Sale!

R1,999.00 R1,442.00
- Product Details :
- Features:
- 1000VA line interactive UPS
- Microprocessor control guarantees high reliability
- Boost and buck AVR for voltage stabilization
- Auto restart while AC is recovering
- Simulated sine wave
- Off-mode charging
- Cold start function
- USB communication port and RJ-11/RJ-45 protection
- Overload, discharge, and overcharge protection
- Supports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
- Battery Type 12V / 7AH x 2 Battery Recharge Time 4-6 hours recover to 90% capacity
- **12 MONTH COMPONENT WARRANTY,6 MONTH BATTERY WARRANTY ON ALL UPS**
- (The Warranty will be void if the UPS is damaged by a Power Surge or Lightning)
-

R3,509.00
- Product Details
- 2000VA/1200W Line Interactive UPS
- Microprocessor control guarantees high reliability
- Boost and buck AVR for voltage stabilization Auto restart while AC is recovering
- Simulated sine wave
- Off-mode charging
- Cold start function
- USB communication port and RJ-11/RJ-45 protection
- Overload, discharge, and overcharge protection
- Supports Windows 2000 / 2003 / 2008 / XP / Vista / 7 / 8, Linux, Unix, and MAC
- **12 MONTH COMPONENT WARRANTY,6 MONTH BATTERY WARRANTY ON ALL UPS**
- (The Warranty will be void if the UPS is damaged by a Power Surge or Lightning)
-
Sale!

R7,754.00 R6,150.00
- Features
- True double-conversion online UPS
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.99
- Output power factor 0.8
- Converter mode available
- ECO mode operation for energy saving (only available for 1-3KVA)
- Generator compatible
- Smart SNMP works well with either USB or RS-232 together (SNMP NETWORK CARD need to be purchased separately)
- Back Time (Minutes)
- 25% Load 400W: 21 minutes
- 50% Load 800W: 7 minutes
- 75% Load 1200W: 4 minutes
- 100% Load 1600W: 2 minutes
- Note:
- Data given are the average values, not the minimum values.
- A UPS is not designed to provide continuous power, merely a window period that allows a computer or other user to finalise the work at hand and shut down. It’s ability to do this is dependent on the number of devices connected to the UPS.
- To establish what you can and cannot connect, calculate the total wattage you need to supply and ensure that the UPS you purchase meets that requirement.
- Specifications
- Colour: Black
- Phase: Single phase with ground
- Capacity: 2000 VA / 1600 W
- INPUT
- Voltage Range
- Low Line Transfer: 160 VAC/140 VAC/120 VAC/110 VAC 5% (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
- Low Line Comeback: 175 VAC /155 VAC/ 135 VAC /125 VAC 5 % (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
- High Line Transfer: 300 VAC 5 %
- High Line Comeback: 290 VAC 5 %
- Frequency Range: 40Hz ~ 70 Hz
- Power Factor: 0.99 @ nominal voltage
- OUTPUT
- Output Voltage: 200/208/220/230/240 VAC
- AC Voltage Regulation (Batt. Mode): 1%
- Frequency Range (Synchronized Range): 47 ~ 53 Hz or 57 ~ 63 Hz
- Frequency Range (Batt. Mode): 50 Hz 0.25 Hz or 60Hz 0.3 Hz
- Current Crest Ratio: 3:1
- Harmonic Distortion: 3 % THD (Linear Load), 6% THD (non-linear load)
- Transfer Time
- AC Mode to Batt. Mode: Zero
- Inverter to Bypass: 4 ms (Typical)
- Waveform (Batt. Mode): Pure Sinewave
- EFFICIENCY
- AC Mode: 89%
- Battery Mode: 87%
- BATTERY
- Battery Type: 12 V / 9 Ah
- Numbers: 4
- Typical Recharge Time: 4 hours recover to 90% capacity
- Charging Voltage: 54.7 VDC 1%
- INDICATORS
- LCD Panel: UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
- ALARM
- Battery Mode: Sounding every 4 seconds
- Low Battery: Sounding every second
- Overload: Sounding twice every second
- Fault: Continuously sounding
- PHYSICAL
- Dimension, D x W x H (mm): 397 x 145 x 220
- Net Weight (kgs): 17
- ENVIRONMENT
- Humidity: 20-90 % RH @ 0- 40 C (non-condensing)
- Noise Level: Less than 50dB @ 1 Meter
- Optional SNMP (SNMP NETWORK CARD need to be purchased separately): Power management from SNMP manager and web browser
- NOTE 1: Derate to 80% of capacity in CVCF mode or when the output voltage is adjusted to 200/208VAC.
- NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m
- What’s in the box
- 1 x UPS Unit
- 1 x VGA Cable
- 2 x MALE TO FEMALE EXTENSION POWER CORD IEC C13-C14 (From UPS to PC)
- 1 x USB Cable (From UPS to PC)
- 1 x Driver Disk
- 1 x User Guide
- 1 x Dedicated Power Cord – Kettle Plug to RED 3 pin (A009
- **12 MONTH COMPONENT WARRANTY,6 MONTH BATTERY WARRANTY ON ALL UPS**
- (The Warranty will be void if the UPS is damaged by a Power Surge or Lightning)
-
Sale!

R5,900.00 R4,195.00
- Key Features:
- Excellent microprocessor control guarantees high reliability
- Boost and buck AVR for voltage stabilization
- Auto restart while AC is recovering
- Simulated sine wave
- Off-mode charging
- Cold start function
- Optional USB/RS-232 communication port and RJ-11/RJ-45 phone protection
- Back Time (Minutes)
- 25% Load 450W: 25 minutes
- 50% Load 900W: 3 minutes 50 seconds
- 75% Load 1350W: 1 minute 50 seconds
- 100% Load 1800W: 40 seconds
- Note:
- Data given are the average values, not the minimum values.
- A UPS is not designed to provide continuous power, merely a window period that allows a computer or other user to finalise the work at hand and shut down. It’s ability to do this is dependent on the number of devices connected to the UPS.
- To establish what you can and cannot connect, calculate the total wattage you need to supply and ensure that the UPS you purchase meets that requirement.
- Specifications
- Model Vesta 3K
- Colour: Black
- Capacity: 3000VA / 1800W
- INPUT
- Voltage: 110/120 VAC or 220/230/240 VAC
- Voltage Range: 81-145 VAC / 162-290 VAC
- Frequency Range: 60/50 Hz (auto sensing)
- OUTPUT
- Output Voltage: 110/120 VAC or 220/230/240 VAC
- AC Voltage Regulation (Batt. Mode): 10%
- Frequency Range (Batt. Mode): 60Hz or 50Hz 1 Hz
- Transfer Time: Typical 2-6 ms, 10ms max.
- Waveform (Batt. Mode): Simulated Sine Wave
- BATTERY
- Battery Type & Number: 12 V/9 AH x 4
- Typical Recharge Time: 4-6 hours recover to 90% capacit
- INDICATORS
- AC Mode: Green lighting
- Battery Mode: Yellow flashing
- Fault: Red lighting
- PROTECTION
- Full Protection: Overload, discharge, and overcharge protection
- ALARM
- Battery Mode: Sounding every 10 second
- Low Battery: Sounding every second
- Overload: Sounding every 0.5 second
- Battery Replacement Alarm: Sounding every 2 seconds
- Fault: Continuously sounding
- PHYSICAL
- Dimension, D x W x H (mm): 495 x 150 x 250
- Net Weight (kgs): 24.8
- OPERATING ENVIRONMENT
- Humidity: 0-90 % RH @ 0- 40 C (non-condensing)
- Noise Level: Less than 40dB
- MANAGEMENT
- Optional USB/RS-232 Port (Need to be purchased separately)
- Supports Windows 2000/2003/XP/Vista/2008/7,
- Linux, Unix, and MAC
- What’s in the box
- 1 x UPS Unit
- 1 x User Manual
- 2 x MALE TO FEMALE EXTENSION POWER CORD IEC C13-C14 (From UPS to PC)
- 1 x USB Cable (From UPS to PC)
- 1 x Driver Disk
- 1 x Dedicated C19 to RED 3 pin plug power cable (CAB-C19)
- **12 MONTH COMPONENT WARRANTY,6 MONTH BATTERY WARRANTY ON ALL UPS**
- (The Warranty will be void if the UPS is damaged by a Power Surge or Lightning)
-
Sale!


R10,422.00 R8,266.00
- Product Features:
- True double-conversion online UPS
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.99
- Output power factor 0.8
- Converter mode available
- ECO mode operation for energy saving (only available for 1-3KVA)
- Generator compatible
- Smart SNMP works well with either USB or RS-232 together (SNMP NETWORK CARD need to be purchased separately)
- Specifications
- Colour
- Black
- PHASE
- Single phase with ground
- CAPACITY
- 3000 VA / 2400 W
- INPUT
- Voltage Range
- Low Line Transfer
- 160 VAC/140 VAC/120 VAC/110 VAC ± 5% (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
- Low Line Comeback
- 175 VAC /155 VAC/ 135 VAC /125 VAC± 5 % (Ambient Temp. (based on load percentage 100% – 80 % / 80 % – 70 % / 70 -60 % / 60 % – 0)
- High Line Transfer
300 VAC ± 5 %
- High Line Comeback
290 VAC ± 5 %
- Frequency Range
40Hz ~ 70 Hz
- Power Factor
? 0.99 @ nominal voltage
- OUTPUT
- Output Voltage
200/208/220/230/240 VAC
- AC Voltage Regulation (Batt. Mode)
± 1%
- Frequency Range (Synchronized Range)
47 ~ 53 Hz or 57 ~ 63 Hz
- Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
- Current Crest Ratio
3:1
- Harmonic Distortion
? 3 % THD (Linear Load),
? 6% THD (non-linear load)
- Transfer Time
- AC Mode to Batt. Mode
Zero
- Inverter to Bypass
4 ms (Typical)
- **12 MONTH COMPONENT WARRANTY,6 MONTH BATTERY WARRANTY ON ALL UPS**
- (The Warranty will be void if the UPS is damaged by a Power Surge or Lightning)
-
Sale!

R4,419.00 R3,505.00
Description
- ME-1000-WPTU+
- 1000VA On-Line Tower UPS Unit & Rated Output: Up to 800W
- Power Factor: ? 0.99 @ Nominal Voltage
- Switching Time: 4ms to Bypass, 0ms to Battery
- Battery Efficiency: 83% (Discharging)
- Recharge Time: 4 Hours to 90% Fan Noise Level: < 50dB @ 1 Meter
- Colour: Black
- Includes 2x 12V 9Ah Lead Acid Batteries
- 1x Standard Plug Point, 2x Power Lead Points
- Serial RS-232 & USB Configuration
- Supports Windows 2000 and Later, Linux x86-64, UNIX, macOS
- **12 MONTH COMPONENT WARRANTY,6 MONTH BATTERY WARRANTY ON ALL UPS**
- (The Warranty will be void if the UPS is damaged by a Power Surge or Lightning)